Rated voltage400V
Rated current100A
Current limiting class-
Release characteristicC
Built-in depth47mm
Frequency50 - 60Hz
Over voltage category4
Width in number of modular spacings6
Connectable conductor cross section solid-core16 - 70mm²
Rated insulation voltage Ui690V
Degree of protection (IP)IP20
Explosion-proofNo
Number of protected poles4
Concurrently switching neutral conductorYes
Pollution degree3
Voltage typeAC/DC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Ambient temperature during operating-30 - 70°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Flush-mounted installationNo
Number of poles (total)4
Connectable conductor cross section multi-wired10 - 50mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated impulse withstand voltage Uimp8kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

18660 | Prekidac Minijat. NG125N 25KA 4P 100A C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated voltage

400V

Rated current

100A

Current limiting class

-

Release characteristic

C

Built-in depth

47mm

Frequency

50 .. 60Hz

Over voltage category

4

Width in number of modular spacings

6

Connectable conductor cross section solid-core

16 .. 70mm²

Rated insulation voltage Ui

690V

Degree of protection (IP)

IP20

Explosion-proof

Number of protected poles

4

Concurrently switching neutral conductor

Pollution degree

3

Voltage type

AC/DC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Ambient temperature during operating

-30 .. 70°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Flush-mounted installation

Number of poles (total)

4

Connectable conductor cross section multi-wired

10 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated impulse withstand voltage Uimp

8kV