Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Current limiting class-
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Built-in depth47mm
Rated insulation voltage Ui690V
Voltage typeAC/DC
Rated current80A
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Frequency50 - 60Hz
Release characteristicB
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated impulse withstand voltage Uimp8kV
Rated voltage400V
Flush-mounted installationNo
Number of protected poles4
Power loss5.6W
Number of poles (total)4
Additional equipment possibleYes
Pollution degree3
Concurrently switching neutral conductorYes
Over voltage category4
Degree of protection (IP)IP20
Width in number of modular spacings6
Ambient temperature during operating-30 - 70°C
Connectable conductor cross section solid-core16 - 70mm²
Explosion-proofNo
Connectable conductor cross section multi-wired10 - 50mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

18666

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Current limiting class

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Built-in depth

47mm

Rated insulation voltage Ui

690V

Voltage type

AC/DC

Rated current

80A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Frequency

50 .. 60Hz

Release characteristic

B

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated impulse withstand voltage Uimp

8kV

Rated voltage

400V

Flush-mounted installation

Number of protected poles

4

Power loss

5.6W

Number of poles (total)

4

Additional equipment possible

Pollution degree

3

Concurrently switching neutral conductor

Over voltage category

4

Degree of protection (IP)

IP20

Width in number of modular spacings

6

Ambient temperature during operating

-30 .. 70°C

Connectable conductor cross section solid-core

16 .. 70mm²

Explosion-proof

Connectable conductor cross section multi-wired

10 .. 50mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.