  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Frequency50 - 60Hz
Current limiting class-
Built-in depth47mm
Rated current125A
Voltage typeAC/DC
Rated insulation voltage Ui690V
Rated voltage400V
Over voltage category4
Number of protected poles3
Pollution degree3
Explosion-proofNo
Degree of protection (IP)IP20
Release characteristicD
Width in number of modular spacings4.5
Additional equipment possibleYes
Concurrently switching neutral conductorNo
Ambient temperature during operating-30 - 70°C
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Connectable conductor cross section multi-wired10 - 50mm²
Connectable conductor cross section solid-core16 - 70mm²
Number of poles (total)3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated impulse withstand voltage Uimp8kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

18671 | Prekidac Minijat. NG125N 25KA 3P 125A D

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Frequency

50 .. 60Hz

Current limiting class

-

Built-in depth

47mm

Rated current

125A

Voltage type

AC/DC

Rated insulation voltage Ui

690V

Rated voltage

400V

Over voltage category

4

Number of protected poles

3

Pollution degree

3

Explosion-proof

Degree of protection (IP)

IP20

Release characteristic

D

Width in number of modular spacings

4.5

Additional equipment possible

Concurrently switching neutral conductor

Ambient temperature during operating

-30 .. 70°C

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Connectable conductor cross section multi-wired

10 .. 50mm²

Connectable conductor cross section solid-core

16 .. 70mm²

Number of poles (total)

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated impulse withstand voltage Uimp

8kV