Technical specifications

Rated current20A
Concurrently switching neutral conductorYes
Flush-mounted installationNo
Frequency50 - 60Hz
Number of protected poles2
Pollution degree3
Voltage typeAC/DC
Degree of protection (IP)IP20
Explosion-proofNo
Current limiting class-
Suitable for flush-mounted installationNo
Width in number of modular spacings3
Rated insulation voltage Ui690V
Additional equipment possibleYes
Over voltage category4
Release characteristicB
Connectable conductor cross section solid-core1.5 - 50mm²
Connectable conductor cross section multi-wired1 - 35mm²
Ambient temperature during operating-30 - 70°C
Built-in depth47mm
Rated voltage230V
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V100kA
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

18752 | Prekidac Minijat. NG125L 50KA 2P 20A B

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated current

20A

Concurrently switching neutral conductor

Flush-mounted installation

Frequency

50 .. 60Hz

Number of protected poles

2

Pollution degree

3

Voltage type

AC/DC

Degree of protection (IP)

IP20

Explosion-proof

Current limiting class

-

Suitable for flush-mounted installation

Width in number of modular spacings

3

Rated insulation voltage Ui

690V

Additional equipment possible

Over voltage category

4

Release characteristic

B

Connectable conductor cross section solid-core

1.5 .. 50mm²

Connectable conductor cross section multi-wired

1 .. 35mm²

Ambient temperature during operating

-30 .. 70°C

Built-in depth

47mm

Rated voltage

230V

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA