  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Frequency50 - 60Hz
Rated current20A
Built-in depth47mm
Release characteristicB
Rated voltage400V
Voltage typeAC/DC
Rated insulation voltage Ui690V
Degree of protection (IP)IP20
Concurrently switching neutral conductorYes
Explosion-proofNo
Over voltage category4
Number of protected poles4
Connectable conductor cross section multi-wired1 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Ambient temperature during operating-30 - 70°C
Pollution degree3
Additional equipment possibleYes
Connectable conductor cross section solid-core1.5 - 50mm²
Current limiting class-
Width in number of modular spacings6
Number of poles (total)4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V100kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated impulse withstand voltage Uimp8kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

18770 | Prekidac Minijat. NG125L 50KA 4P 20A B

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Frequency

50 .. 60Hz

Rated current

20A

Built-in depth

47mm

Release characteristic

B

Rated voltage

400V

Voltage type

AC/DC

Rated insulation voltage Ui

690V

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Explosion-proof

Over voltage category

4

Number of protected poles

4

Connectable conductor cross section multi-wired

1 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Ambient temperature during operating

-30 .. 70°C

Pollution degree

3

Additional equipment possible

Connectable conductor cross section solid-core

1.5 .. 50mm²

Current limiting class

-

Width in number of modular spacings

6

Number of poles (total)

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated impulse withstand voltage Uimp

8kV