  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Release characteristicB
Rated current50A
Built-in depth47mm
Voltage typeAC/DC
Frequency50 - 60Hz
Rated voltage400V
Rated insulation voltage Ui690V
Current limiting class-
Connectable conductor cross section solid-core1.5 - 50mm²
Number of protected poles4
Concurrently switching neutral conductorYes
Explosion-proofNo
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Pollution degree3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired1 - 35mm²
Width in number of modular spacings6
Number of poles (total)4
Ambient temperature during operating-30 - 70°C
Over voltage category4
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V100kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

18774 | Prekidac Minijat. NG125L 50KA 4P 50A B

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Release characteristic

B

Rated current

50A

Built-in depth

47mm

Voltage type

AC/DC

Frequency

50 .. 60Hz

Rated voltage

400V

Rated insulation voltage Ui

690V

Current limiting class

-

Connectable conductor cross section solid-core

1.5 .. 50mm²

Number of protected poles

4

Concurrently switching neutral conductor

Explosion-proof

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Pollution degree

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

1 .. 35mm²

Width in number of modular spacings

6

Number of poles (total)

4

Ambient temperature during operating

-30 .. 70°C

Over voltage category

4

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA