Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Built-in depth47mm
Voltage typeAC/DC
Rated current50A
Frequency50 - 60Hz
Rated voltage400V
Release characteristicC
Over voltage category4
Width in number of modular spacings1.5
Number of protected poles1
Current limiting class-
Degree of protection (IP)IP20
Pollution degree3
Concurrently switching neutral conductorNo
Suitable for flush-mounted installationNo
Explosion-proofNo
Number of poles (total)1
Connectable conductor cross section solid-core1.5 - 50mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V12.5kA
Additional equipment possibleYes
Ambient temperature during operating-30 - 70°C
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Connectable conductor cross section multi-wired1 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated insulation voltage Ui690V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated impulse withstand voltage Uimp8kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

18783 | Prekidac Minijat. NG125L 50KA 1P 50A C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Built-in depth

47mm

Voltage type

AC/DC

Rated current

50A

Frequency

50 .. 60Hz

Rated voltage

400V

Release characteristic

C

Over voltage category

4

Width in number of modular spacings

1.5

Number of protected poles

1

Current limiting class

-

Degree of protection (IP)

IP20

Pollution degree

3

Concurrently switching neutral conductor

Suitable for flush-mounted installation

Explosion-proof

Number of poles (total)

1

Connectable conductor cross section solid-core

1.5 .. 50mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

12.5kA

Additional equipment possible

Ambient temperature during operating

-30 .. 70°C

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Connectable conductor cross section multi-wired

1 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated insulation voltage Ui

690V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated impulse withstand voltage Uimp

8kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.