Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated voltage240V
Built-in depth47mm
Rated current25A
Voltage typeAC/DC
Width in number of modular spacings3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Pollution degree3
Degree of protection (IP)IP20
Number of poles (total)2
Number of protected poles2
Connectable conductor cross section multi-wired1 - 35mm²
Current limiting class-
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Additional equipment possibleYes
Rated insulation voltage Ui690V
Release characteristicC
Flush-mounted installationNo
Rated impulse withstand voltage Uimp8kV
Concurrently switching neutral conductorYes
Frequency50 - 60Hz
Ambient temperature during operating-30 - 70°C
Connectable conductor cross section solid-core1.5 - 50mm²
Explosion-proofNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V100kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Over voltage category4
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

18791 | Prekidac Minijat. NG125L 50KA 2P 25A C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated voltage

240V

Built-in depth

47mm

Rated current

25A

Voltage type

AC/DC

Width in number of modular spacings

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Pollution degree

3

Degree of protection (IP)

IP20

Number of poles (total)

2

Number of protected poles

2

Connectable conductor cross section multi-wired

1 .. 35mm²

Current limiting class

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Additional equipment possible

Rated insulation voltage Ui

690V

Release characteristic

C

Flush-mounted installation

Rated impulse withstand voltage Uimp

8kV

Concurrently switching neutral conductor

Frequency

50 .. 60Hz

Ambient temperature during operating

-30 .. 70°C

Connectable conductor cross section solid-core

1.5 .. 50mm²

Explosion-proof

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Over voltage category

4