Current limiting class-
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Built-in depth47mm
Voltage typeAC/DC
Number of poles (total)2
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V100kA
Rated current50A
Rated voltage240V
Number of protected poles2
Release characteristicC
Rated insulation voltage Ui690V
Frequency50 - 60Hz
Additional equipment possibleYes
Over voltage category4
Width in number of modular spacings3
Connectable conductor cross section multi-wired1 - 35mm²
Connectable conductor cross section solid-core1.5 - 50mm²
Degree of protection (IP)IP20
Concurrently switching neutral conductorYes
Ambient temperature during operating-30 - 70°C
Flush-mounted installationNo
Explosion-proofNo
Pollution degree3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

18794

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Current limiting class

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Built-in depth

47mm

Voltage type

AC/DC

Number of poles (total)

2

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

Rated current

50A

Rated voltage

240V

Number of protected poles

2

Release characteristic

C

Rated insulation voltage Ui

690V

Frequency

50 .. 60Hz

Additional equipment possible

Over voltage category

4

Width in number of modular spacings

3

Connectable conductor cross section multi-wired

1 .. 35mm²

Connectable conductor cross section solid-core

1.5 .. 50mm²

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Ambient temperature during operating

-30 .. 70°C

Flush-mounted installation

Explosion-proof

Pollution degree

3