Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Current limiting class-
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Built-in depth47mm
Release characteristicC
Rated current80A
Rated insulation voltage Ui690V
Number of protected poles2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V100kA
Voltage typeAC/DC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Over voltage category4
Rated impulse withstand voltage Uimp8kV
Flush-mounted installationNo
Frequency50 - 60Hz
Rated voltage240V
Pollution degree3
Additional equipment possibleYes
Width in number of modular spacings3
Connectable conductor cross section solid-core16 - 70mm²
Number of poles (total)2
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired10 - 50mm²
Concurrently switching neutral conductorYes
Explosion-proofNo
Ambient temperature during operating-30 - 70°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

18796

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Current limiting class

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Built-in depth

47mm

Release characteristic

C

Rated current

80A

Rated insulation voltage Ui

690V

Number of protected poles

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

Voltage type

AC/DC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Over voltage category

4

Rated impulse withstand voltage Uimp

8kV

Flush-mounted installation

Frequency

50 .. 60Hz

Rated voltage

240V

Pollution degree

3

Additional equipment possible

Width in number of modular spacings

3

Connectable conductor cross section solid-core

16 .. 70mm²

Number of poles (total)

2

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

10 .. 50mm²

Concurrently switching neutral conductor

Explosion-proof

Ambient temperature during operating

-30 .. 70°C

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.