Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated voltage240V
Frequency50 - 60Hz
Built-in depth47mm
Rated current80A
Voltage typeAC/DC
Release characteristicC
Current limiting class-
Rated insulation voltage Ui690V
Number of protected poles2
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired10 - 50mm²
Pollution degree3
Ambient temperature during operating-30 - 70°C
Width in number of modular spacings3
Connectable conductor cross section solid-core16 - 70mm²
Concurrently switching neutral conductorYes
Explosion-proofNo
Over voltage category4
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V100kA
Number of poles (total)2
Additional equipment possibleYes
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

18796 | Prekidac Minijat. NG125L 50KA 2P 80A C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated voltage

240V

Frequency

50 .. 60Hz

Built-in depth

47mm

Rated current

80A

Voltage type

AC/DC

Release characteristic

C

Current limiting class

-

Rated insulation voltage Ui

690V

Number of protected poles

2

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

10 .. 50mm²

Pollution degree

3

Ambient temperature during operating

-30 .. 70°C

Width in number of modular spacings

3

Connectable conductor cross section solid-core

16 .. 70mm²

Concurrently switching neutral conductor

Explosion-proof

Over voltage category

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

Number of poles (total)

2

Additional equipment possible

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA