  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Suitable for flush-mounted installationNo
Current limiting class-
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Number of protected poles1
Built-in depth47mm
Rated impulse withstand voltage Uimp8kV
Rated insulation voltage Ui690V
Rated current10A
Flush-mounted installationNo
Rated voltage400V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V12.5kA
Concurrently switching neutral conductorNo
Voltage typeAC/DC
Frequency50 - 60Hz
Release characteristicD
Additional equipment possibleYes
Width in number of modular spacings1.5
Number of poles (total)1
Connectable conductor cross section solid-core1.5 - 50mm²
Explosion-proofNo
Over voltage category4
Ambient temperature during operating-30 - 70°C
Connectable conductor cross section multi-wired1 - 35mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Degree of protection (IP)IP20
Pollution degree3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

18830

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Suitable for flush-mounted installation

Current limiting class

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Number of protected poles

1

Built-in depth

47mm

Rated impulse withstand voltage Uimp

8kV

Rated insulation voltage Ui

690V

Rated current

10A

Flush-mounted installation

Rated voltage

400V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

12.5kA

Concurrently switching neutral conductor

Voltage type

AC/DC

Frequency

50 .. 60Hz

Release characteristic

D

Additional equipment possible

Width in number of modular spacings

1.5

Number of poles (total)

1

Connectable conductor cross section solid-core

1.5 .. 50mm²

Explosion-proof

Over voltage category

4

Ambient temperature during operating

-30 .. 70°C

Connectable conductor cross section multi-wired

1 .. 35mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Degree of protection (IP)

IP20

Pollution degree

3