Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Current limiting class-
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Built-in depth47mm
Number of protected poles1
Release characteristicD
Voltage typeAC/DC
Number of poles (total)1
Rated current16A
Frequency50 - 60Hz
Rated voltage400V
Pollution degree3
Additional equipment possibleYes
Ambient temperature during operating-30 - 70°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V12.5kA
Concurrently switching neutral conductorNo
Over voltage category4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Explosion-proofNo
Connectable conductor cross section solid-core1.5 - 50mm²
Width in number of modular spacings1.5
Flush-mounted installationNo
Connectable conductor cross section multi-wired1 - 35mm²
Rated insulation voltage Ui690V
Degree of protection (IP)IP20
Rated impulse withstand voltage Uimp8kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

18831

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Current limiting class

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Built-in depth

47mm

Number of protected poles

1

Release characteristic

D

Voltage type

AC/DC

Number of poles (total)

1

Rated current

16A

Frequency

50 .. 60Hz

Rated voltage

400V

Pollution degree

3

Additional equipment possible

Ambient temperature during operating

-30 .. 70°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

12.5kA

Concurrently switching neutral conductor

Over voltage category

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Explosion-proof

Connectable conductor cross section solid-core

1.5 .. 50mm²

Width in number of modular spacings

1.5

Flush-mounted installation

Connectable conductor cross section multi-wired

1 .. 35mm²

Rated insulation voltage Ui

690V

Degree of protection (IP)

IP20

Rated impulse withstand voltage Uimp

8kV

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.