Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Current limiting class-
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Number of protected poles2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated voltage240V
Built-in depth47mm
Release characteristicD
Rated current25A
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V100kA
Flush-mounted installationNo
Rated impulse withstand voltage Uimp8kV
Voltage typeAC/DC
Pollution degree3
Additional equipment possibleYes
Degree of protection (IP)IP20
Frequency50 - 60Hz
Over voltage category4
Concurrently switching neutral conductorYes
Ambient temperature during operating-30 - 70°C
Rated insulation voltage Ui690V
Width in number of modular spacings3
Connectable conductor cross section multi-wired1 - 35mm²
Connectable conductor cross section solid-core1.5 - 50mm²
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

18842

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Current limiting class

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Number of protected poles

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated voltage

240V

Built-in depth

47mm

Release characteristic

D

Rated current

25A

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

Flush-mounted installation

Rated impulse withstand voltage Uimp

8kV

Voltage type

AC/DC

Pollution degree

3

Additional equipment possible

Degree of protection (IP)

IP20

Frequency

50 .. 60Hz

Over voltage category

4

Concurrently switching neutral conductor

Ambient temperature during operating

-30 .. 70°C

Rated insulation voltage Ui

690V

Width in number of modular spacings

3

Connectable conductor cross section multi-wired

1 .. 35mm²

Connectable conductor cross section solid-core

1.5 .. 50mm²

Explosion-proof

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.