Technical specifications

Number of protected poles2
Explosion-proofNo
Rated current32A
Over voltage category4
Rated insulation voltage Ui690V
Pollution degree3
Rated voltage240V
Current limiting class-
Width in number of modular spacings3
Release characteristicD
Voltage typeAC/DC
Frequency50 - 60Hz
Built-in depth47mm
Concurrently switching neutral conductorYes
Degree of protection (IP)IP20
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V100kA
Connectable conductor cross section multi-wired1 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Connectable conductor cross section solid-core1.5 - 50mm²
Number of poles (total)2
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Flush-mounted installationNo
Ambient temperature during operating-30 - 70°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

18843 | Prekidac Minijat. NG125L 50KA 2P 32A D

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of protected poles

2

Explosion-proof

Rated current

32A

Over voltage category

4

Rated insulation voltage Ui

690V

Pollution degree

3

Rated voltage

240V

Current limiting class

-

Width in number of modular spacings

3

Release characteristic

D

Voltage type

AC/DC

Frequency

50 .. 60Hz

Built-in depth

47mm

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

Connectable conductor cross section multi-wired

1 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Connectable conductor cross section solid-core

1.5 .. 50mm²

Number of poles (total)

2

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Flush-mounted installation

Ambient temperature during operating

-30 .. 70°C

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.