Technical specifications

Rated voltage240V
Frequency50 - 60Hz
Voltage typeAC/DC
Rated insulation voltage Ui690V
Built-in depth47mm
Current limiting class-
Connectable conductor cross section multi-wired1 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Degree of protection (IP)IP20
Flush-mounted installationNo
Ambient temperature during operating-30 - 70°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Pollution degree3
Explosion-proofNo
Number of protected poles2
Width in number of modular spacings3
Additional equipment possibleYes
Concurrently switching neutral conductorYes
Connectable conductor cross section solid-core1.5 - 50mm²
Over voltage category4
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V100kA
Rated current40A
Release characteristicD
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

18844 | Prekidac Minijat. NG125L 50KA 2P 40A D

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated voltage

240V

Frequency

50 .. 60Hz

Voltage type

AC/DC

Rated insulation voltage Ui

690V

Built-in depth

47mm

Current limiting class

-

Connectable conductor cross section multi-wired

1 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Degree of protection (IP)

IP20

Flush-mounted installation

Ambient temperature during operating

-30 .. 70°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Pollution degree

3

Explosion-proof

Number of protected poles

2

Width in number of modular spacings

3

Additional equipment possible

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

1.5 .. 50mm²

Over voltage category

4

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

Rated current

40A

Release characteristic

D

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA