Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Frequency50 - 60Hz
Rated voltage415V
Built-in depth47mm
Rated current40A
Voltage typeAC/DC
Current limiting class-
Rated insulation voltage Ui690V
Release characteristicD
Number of protected poles3
Width in number of modular spacings4.5
Over voltage category4
Pollution degree3
Degree of protection (IP)IP20
Explosion-proofNo
Number of poles (total)3
Ambient temperature during operating-30 - 70°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Connectable conductor cross section multi-wired1 - 35mm²
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core1.5 - 50mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V100kA
Rated impulse withstand voltage Uimp8kV
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

18853 | Prekidac Minijat. NG125L 50KA 3P 40A D

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Frequency

50 .. 60Hz

Rated voltage

415V

Built-in depth

47mm

Rated current

40A

Voltage type

AC/DC

Current limiting class

-

Rated insulation voltage Ui

690V

Release characteristic

D

Number of protected poles

3

Width in number of modular spacings

4.5

Over voltage category

4

Pollution degree

3

Degree of protection (IP)

IP20

Explosion-proof

Number of poles (total)

3

Ambient temperature during operating

-30 .. 70°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Connectable conductor cross section multi-wired

1 .. 35mm²

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

1.5 .. 50mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

Rated impulse withstand voltage Uimp

8kV

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.