Technical specifications

Current limiting class-
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Additional equipment possibleYes
Degree of protection (IP)IP20
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V100kA
Connectable conductor cross section solid-core1.5 - 50mm²
Explosion-proofNo
Number of poles (total)2
Rated voltage230V
Frequency50 - 60Hz
Built-in depth47mm
Number of protected poles2
Pollution degree3
Rated current4A
Rated insulation voltage Ui690V
Rated impulse withstand voltage Uimp8kV
Release characteristicMA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Voltage typeAC/DC
Over voltage category4
Ambient temperature during operating-30 - 70°C
Flush-mounted installationNo
Connectable conductor cross section multi-wired1 - 35mm²
Width in number of modular spacings3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

18868

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Current limiting class

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Additional equipment possible

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

Connectable conductor cross section solid-core

1.5 .. 50mm²

Explosion-proof

Number of poles (total)

2

Rated voltage

230V

Frequency

50 .. 60Hz

Built-in depth

47mm

Number of protected poles

2

Pollution degree

3

Rated current

4A

Rated insulation voltage Ui

690V

Rated impulse withstand voltage Uimp

8kV

Release characteristic

MA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Voltage type

AC/DC

Over voltage category

4

Ambient temperature during operating

-30 .. 70°C

Flush-mounted installation

Connectable conductor cross section multi-wired

1 .. 35mm²

Width in number of modular spacings

3