Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Suitable for flush-mounted installationNo
Current limiting class-
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Connectable conductor cross section multi-wired1 - 35mm²
Rated insulation voltage Ui690V
Width in number of modular spacings3
Degree of protection (IP)IP20
Voltage typeAC/DC
Ambient temperature during operating-30 - 70°C
Rated voltage230V
Over voltage category4
Number of protected poles2
Explosion-proofNo
Additional equipment possibleYes
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Release characteristicMA
Connectable conductor cross section solid-core1.5 - 50mm²
Built-in depth47mm
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V100kA
Rated impulse withstand voltage Uimp8kV
Number of poles (total)2
Pollution degree3
Frequency50 - 60Hz
Concurrently switching neutral conductorYes
Rated current10A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

18870

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Suitable for flush-mounted installation

Current limiting class

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Connectable conductor cross section multi-wired

1 .. 35mm²

Rated insulation voltage Ui

690V

Width in number of modular spacings

3

Degree of protection (IP)

IP20

Voltage type

AC/DC

Ambient temperature during operating

-30 .. 70°C

Rated voltage

230V

Over voltage category

4

Number of protected poles

2

Explosion-proof

Additional equipment possible

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Release characteristic

MA

Connectable conductor cross section solid-core

1.5 .. 50mm²

Built-in depth

47mm

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

Rated impulse withstand voltage Uimp

8kV

Number of poles (total)

2

Pollution degree

3

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Rated current

10A

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.