Aleta.hr
Main Product Image

18874

Code: 1690423

ManufacturerRAZNO
Catalog number18874
Type
EAN code3303430188742

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Current limiting class

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated current

40A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

Rated impulse withstand voltage Uimp

8kV

Release characteristic

MA

Voltage type

AC/DC

Rated voltage

230V

Rated insulation voltage Ui

690V

Frequency

50 - 60Hz

Width in number of modular spacings

3

Pollution degree

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Additional equipment possible

Yes

Number of protected poles

2

Concurrently switching neutral conductor

Yes

Degree of protection (IP)

IP20

Over voltage category

4

Ambient temperature during operating

-30 - 70°C

Built-in depth

47mm

Connectable conductor cross section multi-wired

1 - 35mm²

Connectable conductor cross section solid-core

1.5 - 50mm²

Flush-mounted installation

No

Explosion-proof

No

Number of poles (total)

2


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

18874

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Current limiting class

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated current

40A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

Rated impulse withstand voltage Uimp

8kV

Release characteristic

MA

Voltage type

AC/DC

Rated voltage

230V

Rated insulation voltage Ui

690V

Frequency

50 .. 60Hz

Width in number of modular spacings

3

Pollution degree

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Additional equipment possible

Number of protected poles

2

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Over voltage category

4

Ambient temperature during operating

-30 .. 70°C

Built-in depth

47mm

Connectable conductor cross section multi-wired

1 .. 35mm²

Connectable conductor cross section solid-core

1.5 .. 50mm²

Flush-mounted installation

Explosion-proof

Number of poles (total)

2

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.