Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Release characteristicMA
Rated voltage400V
Number of protected poles3
Rated insulation voltage Ui690V
Rated current10A
Ambient temperature during operating-30 - 70°C
Voltage typeAC/DC
Pollution degree3
Width in number of modular spacings4.5
Explosion-proofNo
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Frequency50 - 60Hz
Built-in depth47mm
Over voltage category4
Current limiting class-
Connectable conductor cross section multi-wired1 - 35mm²
Connectable conductor cross section solid-core1.5 - 50mm²
Flush-mounted installationNo
Number of poles (total)3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V100kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

18881 | Prekidac Minijaturni NG125L 3P 10A MA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Release characteristic

MA

Rated voltage

400V

Number of protected poles

3

Rated insulation voltage Ui

690V

Rated current

10A

Ambient temperature during operating

-30 .. 70°C

Voltage type

AC/DC

Pollution degree

3

Width in number of modular spacings

4.5

Explosion-proof

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Frequency

50 .. 60Hz

Built-in depth

47mm

Over voltage category

4

Current limiting class

-

Connectable conductor cross section multi-wired

1 .. 35mm²

Connectable conductor cross section solid-core

1.5 .. 50mm²

Flush-mounted installation

Number of poles (total)

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.