

Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- SCHNEIDER
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Conditioned rated short-circuit current Iq
-kA
Switching power at 400 V
-kW
Rated operation power at AC-23, 400 V
-kW
Rated permanent current at AC-21, 400 V
-A
Rated permanent current at AC-23, 400 V
125A
Version as emergency stop installation
No
Rated short-time withstand current lcw
1.5kA
Rated permanent current Iu
125A
Version as maintenance-/service switch
No
Rated operating voltage
500 - 500V
Version as reversing switch
No
Version as main switch
Yes
Version as safety switch
Yes
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as change-over contact
0
Max. rated operation voltage Ue AC
500V
Number of auxiliary contacts as normally open contact
0
Motor drive optional
No
Number of auxiliary contacts as normally closed contact
0
Suitable for floor mounting
No
Motor drive integrated
No
Voltage release optional
Yes
Number of switches
4
Number of poles
4
Suitable for front mounting 4-hole
Yes
Suitable for distribution board installation
Yes
Suitable for front mounting centre
Yes
Suitable for intermediate mounting
No
Colour control element
Black
Type of control element
Toggle
Interlockable
No
Type of electrical connection of main circuit
Screw connection
Degree of protection (IP), front side
IP20
18896

Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- SCHNEIDER
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Conditioned rated short-circuit current Iq
-kA
Switching power at 400 V
-kW
Rated operation power at AC-23, 400 V
-kW
Rated permanent current at AC-21, 400 V
-A
Rated permanent current at AC-23, 400 V
125A
Version as emergency stop installation
Rated short-time withstand current lcw
1.5kA
Rated permanent current Iu
125A
Version as maintenance-/service switch
Rated operating voltage
500 .. 500V
Version as reversing switch
Version as main switch
Version as safety switch
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as change-over contact
0
Max. rated operation voltage Ue AC
500V
Number of auxiliary contacts as normally open contact
0
Motor drive optional
Number of auxiliary contacts as normally closed contact
0
Suitable for floor mounting
Motor drive integrated
Voltage release optional
Number of switches
4
Number of poles
4
Suitable for front mounting 4-hole
Suitable for distribution board installation
Suitable for front mounting centre
Suitable for intermediate mounting
Colour control element
Black
Type of control element
Toggle
Interlockable
Type of electrical connection of main circuit
Screw connection
Degree of protection (IP), front side
IP20
We use cookies to enhance your experience.