Aleta.hr

Details

  • Low-voltage industrial components
  • Switch disconnector
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated operation power at AC-3, 400 V-kW
Conditioned rated short-circuit current Iq36kA
Rated permanent current at AC-21, 400 V-A
Switching power at 400 V-kW
Version as main switchYes
Version as maintenance-/service switchYes
Version as reversing switchNo
Version as emergency stop installationYes
Max. rated operation voltage Ue AC690V
Number of poles4
Rated operating voltage690 - 690V
Number of auxiliary contacts as normally open contact0
Rated operation power at AC-23, 400 V90kW
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu200A
Version as safety switchNo
Voltage release optionalNo
Rated short-time withstand current lcw8.5kA
Motor drive optionalNo
Motor drive integratedNo
Device constructionBuilt-in device fixed built-in technique
Suitable for front mounting 4-holeYes
Suitable for front mounting centreYes
Number of auxiliary contacts as change-over contact2
Rated permanent current at AC-23, 400 V200A
Suitable for floor mountingYes
Number of switches1
Colour control elementRed
Suitable for distribution board installationYes
Degree of protection (IP), front sideIP40
InterlockableYes
Type of control elementLong turning handle
Type of electrical connection of main circuitScrew connection
Suitable for intermediate mountingNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

31123

Main Product Image

Details

  • Low-voltage industrial components
  • Switch disconnector
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated operation power at AC-3, 400 V

-kW

Conditioned rated short-circuit current Iq

36kA

Rated permanent current at AC-21, 400 V

-A

Switching power at 400 V

-kW

Version as main switch

Version as maintenance-/service switch

Version as reversing switch

Version as emergency stop installation

Max. rated operation voltage Ue AC

690V

Number of poles

4

Rated operating voltage

690 .. 690V

Number of auxiliary contacts as normally open contact

0

Rated operation power at AC-23, 400 V

90kW

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

200A

Version as safety switch

Voltage release optional

Rated short-time withstand current lcw

8.5kA

Motor drive optional

Motor drive integrated

Device construction

Built-in device fixed built-in technique

Suitable for front mounting 4-hole

Suitable for front mounting centre

Number of auxiliary contacts as change-over contact

2

Rated permanent current at AC-23, 400 V

200A

Suitable for floor mounting

Number of switches

1

Colour control element

Red

Suitable for distribution board installation

Degree of protection (IP), front side

IP40

Interlockable

Type of control element

Long turning handle

Type of electrical connection of main circuit

Screw connection

Suitable for intermediate mounting

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.