Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting- - -A
Adjustment range undelayed short-circuit release- - -A
Adjustment range short-term delayed short-circuit release- - -A
Rated permanent current Iu800A
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Power loss45W
DIN rail (top hat rail) mounting optionalNo
Device constructionBuilt-in device fixed built-in technique
With integrated under voltage releaseNo
Position of connection for main current circuitFront side
Motor drive optionalYes
Motor drive integratedNo
With switched-off indicatorYes
Degree of protection (IP)IP40
Number of poles3
Type of control elementToggle
Integrated earth fault protectionNo
Type of electrical connection of main circuitBolt connection
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact0
Complete device with protection unitNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

33231

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting

- .. -A

Adjustment range undelayed short-circuit release

- .. -A

Adjustment range short-term delayed short-circuit release

- .. -A

Rated permanent current Iu

800A

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Power loss

45W

DIN rail (top hat rail) mounting optional

Device construction

Built-in device fixed built-in technique

With integrated under voltage release

Position of connection for main current circuit

Front side

Motor drive optional

Motor drive integrated

With switched-off indicator

Degree of protection (IP)

IP40

Number of poles

3

Type of control element

Toggle

Integrated earth fault protection

Type of electrical connection of main circuit

Bolt connection

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

Complete device with protection unit

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.