Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting- - -A
Adjustment range undelayed short-circuit release- - -A
Adjustment range short-term delayed short-circuit release- - -A
Rated voltage690 - 690V
Suitable for DIN rail (top hat rail) mountingNo
Integrated earth fault protectionNo
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu800A
Number of auxiliary contacts as normally open contact0
Type of electrical connection of main circuitBolt connection
Device constructionBuilt-in device fixed built-in technique
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Motor drive integratedNo
Motor drive optionalYes
Number of poles3
Position of connection for main current circuitFront side
DIN rail (top hat rail) mounting optionalNo
Type of control elementToggle
With integrated under voltage releaseNo
With switched-off indicatorYes
Number of auxiliary contacts as change-over contact0
Degree of protection (IP)IP40
Complete device with protection unitNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

33232

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting

- .. -A

Adjustment range undelayed short-circuit release

- .. -A

Adjustment range short-term delayed short-circuit release

- .. -A

Rated voltage

690 .. 690V

Suitable for DIN rail (top hat rail) mounting

Integrated earth fault protection

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

800A

Number of auxiliary contacts as normally open contact

0

Type of electrical connection of main circuit

Bolt connection

Device construction

Built-in device fixed built-in technique

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Motor drive integrated

Motor drive optional

Number of poles

3

Position of connection for main current circuit

Front side

DIN rail (top hat rail) mounting optional

Type of control element

Toggle

With integrated under voltage release

With switched-off indicator

Number of auxiliary contacts as change-over contact

0

Degree of protection (IP)

IP40

Complete device with protection unit

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.