  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting- - -A
Adjustment range undelayed short-circuit release- - -A
Adjustment range short-term delayed short-circuit release- - -A
Rated permanent current Iu1600A
Rated voltage690 - 690V
Position of connection for main current circuitFront side
Integrated earth fault protectionNo
Motor drive integratedNo
Complete device with protection unitNo
With switched-off indicatorYes
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally closed contact0
DIN rail (top hat rail) mounting optionalNo
With integrated under voltage releaseNo
Motor drive optionalYes
Suitable for DIN rail (top hat rail) mountingNo
Device constructionBuilt-in device fixed built-in technique
Number of poles4
Type of electrical connection of main circuitBolt connection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Degree of protection (IP)IP40
Number of auxiliary contacts as normally open contact0
Type of control elementToggle
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

33265

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting

- .. -A

Adjustment range undelayed short-circuit release

- .. -A

Adjustment range short-term delayed short-circuit release

- .. -A

Rated permanent current Iu

1600A

Rated voltage

690 .. 690V

Position of connection for main current circuit

Front side

Integrated earth fault protection

Motor drive integrated

Complete device with protection unit

With switched-off indicator

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally closed contact

0

DIN rail (top hat rail) mounting optional

With integrated under voltage release

Motor drive optional

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device fixed built-in technique

Number of poles

4

Type of electrical connection of main circuit

Bolt connection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Degree of protection (IP)

IP40

Number of auxiliary contacts as normally open contact

0

Type of control element

Toggle