  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting- - -A
Adjustment range undelayed short-circuit release- - -A
Adjustment range short-term delayed short-circuit release- - -A
Type of electrical connection of main circuitBolt connection
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact0
Rated permanent current Iu630A
Number of auxiliary contacts as normally closed contact0
Position of connection for main current circuitFront side
Motor drive integratedYes
With switched-off indicatorYes
Number of poles4
Integrated earth fault protectionNo
Complete device with protection unitNo
Type of control elementPush button
Device constructionBuilt-in device fixed built-in technique
Degree of protection (IP)IP40
Motor drive optionalNo
Suitable for DIN rail (top hat rail) mountingNo
With integrated under voltage releaseNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

33276

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting

- .. -A

Adjustment range undelayed short-circuit release

- .. -A

Adjustment range short-term delayed short-circuit release

- .. -A

Type of electrical connection of main circuit

Bolt connection

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

630A

Number of auxiliary contacts as normally closed contact

0

Position of connection for main current circuit

Front side

Motor drive integrated

With switched-off indicator

Number of poles

4

Integrated earth fault protection

Complete device with protection unit

Type of control element

Push button

Device construction

Built-in device fixed built-in technique

Degree of protection (IP)

IP40

Motor drive optional

Suitable for DIN rail (top hat rail) mounting

With integrated under voltage release

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.