Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting- - -A
Adjustment range undelayed short-circuit release- - -A
Adjustment range short-term delayed short-circuit release- - -A
Integrated earth fault protectionNo
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as normally closed contact0
With switched-off indicatorYes
With integrated under voltage releaseNo
Motor drive integratedYes
Degree of protection (IP)IP40
Number of poles4
Rated permanent current Iu800A
Device constructionBuilt-in device fixed built-in technique
Position of connection for main current circuitFront side
Complete device with protection unitNo
Number of auxiliary contacts as normally open contact0
DIN rail (top hat rail) mounting optionalNo
Type of control elementPush button
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Suitable for DIN rail (top hat rail) mountingNo
Motor drive optionalNo
Number of auxiliary contacts as change-over contact0
Rated voltage690 - 690V
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

33286

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting

- .. -A

Adjustment range undelayed short-circuit release

- .. -A

Adjustment range short-term delayed short-circuit release

- .. -A

Integrated earth fault protection

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as normally closed contact

0

With switched-off indicator

With integrated under voltage release

Motor drive integrated

Degree of protection (IP)

IP40

Number of poles

4

Rated permanent current Iu

800A

Device construction

Built-in device fixed built-in technique

Position of connection for main current circuit

Front side

Complete device with protection unit

Number of auxiliary contacts as normally open contact

0

DIN rail (top hat rail) mounting optional

Type of control element

Push button

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Suitable for DIN rail (top hat rail) mounting

Motor drive optional

Number of auxiliary contacts as change-over contact

0

Rated voltage

690 .. 690V

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.