Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting- - -A
Adjustment range undelayed short-circuit release- - -A
Adjustment range short-term delayed short-circuit release- - -A
Rated voltage690 - 690V
Number of auxiliary contacts as change-over contact0
Integrated earth fault protectionNo
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally open contact0
With integrated under voltage releaseNo
Rated permanent current Iu1000A
Number of auxiliary contacts as normally closed contact0
Device constructionBuilt-in device fixed built-in technique
With switched-off indicatorYes
Number of poles4
Type of electrical connection of main circuitBolt connection
Complete device with protection unitNo
Position of connection for main current circuitFront side
DIN rail (top hat rail) mounting optionalNo
Motor drive integratedYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Degree of protection (IP)IP40
Motor drive optionalNo
Type of control elementPush button
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

33295

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting

- .. -A

Adjustment range undelayed short-circuit release

- .. -A

Adjustment range short-term delayed short-circuit release

- .. -A

Rated voltage

690 .. 690V

Number of auxiliary contacts as change-over contact

0

Integrated earth fault protection

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally open contact

0

With integrated under voltage release

Rated permanent current Iu

1000A

Number of auxiliary contacts as normally closed contact

0

Device construction

Built-in device fixed built-in technique

With switched-off indicator

Number of poles

4

Type of electrical connection of main circuit

Bolt connection

Complete device with protection unit

Position of connection for main current circuit

Front side

DIN rail (top hat rail) mounting optional

Motor drive integrated

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Degree of protection (IP)

IP40

Motor drive optional

Type of control element

Push button

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.