Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting- - -A
Adjustment range undelayed short-circuit release- - -A
Adjustment range short-term delayed short-circuit release- - -A
Rated permanent current Iu630A
With integrated under voltage releaseNo
Position of connection for main current circuitFront side
Degree of protection (IP)IP40
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally closed contact0
Complete device with protection unitNo
Integrated earth fault protectionNo
Device constructionBuilt-in device slide-in technique (withdrawable)
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
DIN rail (top hat rail) mounting optionalNo
With switched-off indicatorYes
Rated voltage690 - 690V
Number of auxiliary contacts as normally open contact0
Motor drive optionalYes
Number of auxiliary contacts as change-over contact0
Type of electrical connection of main circuitBolt connection
Type of control elementToggle
Number of poles4
Motor drive integratedNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

33325

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting

- .. -A

Adjustment range undelayed short-circuit release

- .. -A

Adjustment range short-term delayed short-circuit release

- .. -A

Rated permanent current Iu

630A

With integrated under voltage release

Position of connection for main current circuit

Front side

Degree of protection (IP)

IP40

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally closed contact

0

Complete device with protection unit

Integrated earth fault protection

Device construction

Built-in device slide-in technique (withdrawable)

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

DIN rail (top hat rail) mounting optional

With switched-off indicator

Rated voltage

690 .. 690V

Number of auxiliary contacts as normally open contact

0

Motor drive optional

Number of auxiliary contacts as change-over contact

0

Type of electrical connection of main circuit

Bolt connection

Type of control element

Toggle

Number of poles

4

Motor drive integrated

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.