Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting- - -A
Adjustment range undelayed short-circuit release- - -A
Adjustment range short-term delayed short-circuit release- - -A
Rated permanent current Iu800A
Rated voltage690 - 690V
With switched-off indicatorYes
Number of auxiliary contacts as change-over contact0
Type of control elementToggle
Complete device with protection unitNo
Degree of protection (IP)IP40
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
DIN rail (top hat rail) mounting optionalNo
Motor drive optionalYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Type of electrical connection of main circuitBolt connection
Motor drive integratedNo
Integrated earth fault protectionNo
Device constructionBuilt-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mountingNo
Number of poles4
With integrated under voltage releaseNo
Position of connection for main current circuitFront side
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

33335

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting

- .. -A

Adjustment range undelayed short-circuit release

- .. -A

Adjustment range short-term delayed short-circuit release

- .. -A

Rated permanent current Iu

800A

Rated voltage

690 .. 690V

With switched-off indicator

Number of auxiliary contacts as change-over contact

0

Type of control element

Toggle

Complete device with protection unit

Degree of protection (IP)

IP40

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

DIN rail (top hat rail) mounting optional

Motor drive optional

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Type of electrical connection of main circuit

Bolt connection

Motor drive integrated

Integrated earth fault protection

Device construction

Built-in device slide-in technique (withdrawable)

Suitable for DIN rail (top hat rail) mounting

Number of poles

4

With integrated under voltage release

Position of connection for main current circuit

Front side

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.