Technical specifications

Overload release current setting- - -A
Adjustment range undelayed short-circuit release- - -A
Adjustment range short-term delayed short-circuit release- - -A
Type of electrical connection of main circuitBolt connection
Power loss160W
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Rated permanent current Iu800A
Suitable for DIN rail (top hat rail) mountingNo
With switched-off indicatorYes
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as change-over contact0
Number of poles4
Number of auxiliary contacts as normally open contact0
With integrated under voltage releaseNo
Number of auxiliary contacts as normally closed contact0
Position of connection for main current circuitFront side
Type of control elementToggle
Degree of protection (IP)IP40
Motor drive optionalYes
Complete device with protection unitNo
Motor drive integratedNo
Device constructionBuilt-in device slide-in technique (withdrawable)
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

33336

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting

- .. -A

Adjustment range undelayed short-circuit release

- .. -A

Adjustment range short-term delayed short-circuit release

- .. -A

Type of electrical connection of main circuit

Bolt connection

Power loss

160W

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Rated permanent current Iu

800A

Suitable for DIN rail (top hat rail) mounting

With switched-off indicator

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as change-over contact

0

Number of poles

4

Number of auxiliary contacts as normally open contact

0

With integrated under voltage release

Number of auxiliary contacts as normally closed contact

0

Position of connection for main current circuit

Front side

Type of control element

Toggle

Degree of protection (IP)

IP40

Motor drive optional

Complete device with protection unit

Motor drive integrated

Device construction

Built-in device slide-in technique (withdrawable)