Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting- - -A
Adjustment range undelayed short-circuit release- - -A
Adjustment range short-term delayed short-circuit release- - -A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Rated permanent current Iu1250A
Rated voltage690 - 690V
Device constructionBuilt-in device slide-in technique (withdrawable)
Integrated earth fault protectionNo
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalNo
With switched-off indicatorYes
Number of auxiliary contacts as normally open contact0
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as change-over contact0
Power loss252W
Number of auxiliary contacts as normally closed contact0
With integrated under voltage releaseNo
Complete device with protection unitNo
Motor drive integratedNo
Position of connection for main current circuitFront side
Number of poles3
Type of control elementToggle
Degree of protection (IP)IP40
Motor drive optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

33351

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting

- .. -A

Adjustment range undelayed short-circuit release

- .. -A

Adjustment range short-term delayed short-circuit release

- .. -A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Rated permanent current Iu

1250A

Rated voltage

690 .. 690V

Device construction

Built-in device slide-in technique (withdrawable)

Integrated earth fault protection

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

With switched-off indicator

Number of auxiliary contacts as normally open contact

0

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as change-over contact

0

Power loss

252W

Number of auxiliary contacts as normally closed contact

0

With integrated under voltage release

Complete device with protection unit

Motor drive integrated

Position of connection for main current circuit

Front side

Number of poles

3

Type of control element

Toggle

Degree of protection (IP)

IP40

Motor drive optional

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.