Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting- - -A
Adjustment range undelayed short-circuit release- - -A
Adjustment range short-term delayed short-circuit release- - -A
Power loss336W
Rated permanent current Iu1250A
Device constructionBuilt-in device slide-in technique (withdrawable)
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Suitable for DIN rail (top hat rail) mountingNo
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as normally closed contact0
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
With integrated under voltage releaseNo
With switched-off indicatorYes
Integrated earth fault protectionNo
Number of poles4
Complete device with protection unitNo
Type of control elementToggle
Position of connection for main current circuitFront side
Motor drive integratedNo
Degree of protection (IP)IP40
Motor drive optionalYes
Rated voltage690 - 690V
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

33355

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting

- .. -A

Adjustment range undelayed short-circuit release

- .. -A

Adjustment range short-term delayed short-circuit release

- .. -A

Power loss

336W

Rated permanent current Iu

1250A

Device construction

Built-in device slide-in technique (withdrawable)

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Suitable for DIN rail (top hat rail) mounting

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as normally closed contact

0

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

With integrated under voltage release

With switched-off indicator

Integrated earth fault protection

Number of poles

4

Complete device with protection unit

Type of control element

Toggle

Position of connection for main current circuit

Front side

Motor drive integrated

Degree of protection (IP)

IP40

Motor drive optional

Rated voltage

690 .. 690V

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.