Overload release current setting- - -A
Adjustment range undelayed short-circuit release- - -A
Adjustment range short-term delayed short-circuit release- - -A
Rated permanent current Iu800A
Rated voltage690 - 690V
Type of electrical connection of main circuitBolt connection
Device constructionBuilt-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally open contact0
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally closed contact0
Number of poles3
With switched-off indicatorYes
With integrated under voltage releaseNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Type of control elementPush button
Integrated earth fault protectionNo
Position of connection for main current circuitFront side
Motor drive optionalNo
Complete device with protection unitNo
Suitable for DIN rail (top hat rail) mountingNo
Degree of protection (IP)IP40
Motor drive integratedYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

33380

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting

- .. -A

Adjustment range undelayed short-circuit release

- .. -A

Adjustment range short-term delayed short-circuit release

- .. -A

Rated permanent current Iu

800A

Rated voltage

690 .. 690V

Type of electrical connection of main circuit

Bolt connection

Device construction

Built-in device slide-in technique (withdrawable)

Number of auxiliary contacts as normally open contact

0

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally closed contact

0

Number of poles

3

With switched-off indicator

With integrated under voltage release

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Type of control element

Push button

Integrated earth fault protection

Position of connection for main current circuit

Front side

Motor drive optional

Complete device with protection unit

Suitable for DIN rail (top hat rail) mounting

Degree of protection (IP)

IP40

Motor drive integrated