Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting- - -A
Adjustment range undelayed short-circuit release- - -A
Adjustment range short-term delayed short-circuit release- - -A
Rated permanent current Iu800A
Number of auxiliary contacts as normally closed contact0
Rated voltage690 - 690V
Integrated earth fault protectionNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Device constructionBuilt-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mountingNo
Type of control elementPush button
Type of electrical connection of main circuitBolt connection
Motor drive integratedYes
DIN rail (top hat rail) mounting optionalNo
With integrated under voltage releaseNo
With switched-off indicatorYes
Complete device with protection unitNo
Number of auxiliary contacts as normally open contact0
Position of connection for main current circuitFront side
Number of auxiliary contacts as change-over contact0
Degree of protection (IP)IP40
Number of poles4
Motor drive optionalNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

33384

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting

- .. -A

Adjustment range undelayed short-circuit release

- .. -A

Adjustment range short-term delayed short-circuit release

- .. -A

Rated permanent current Iu

800A

Number of auxiliary contacts as normally closed contact

0

Rated voltage

690 .. 690V

Integrated earth fault protection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Device construction

Built-in device slide-in technique (withdrawable)

Suitable for DIN rail (top hat rail) mounting

Type of control element

Push button

Type of electrical connection of main circuit

Bolt connection

Motor drive integrated

DIN rail (top hat rail) mounting optional

With integrated under voltage release

With switched-off indicator

Complete device with protection unit

Number of auxiliary contacts as normally open contact

0

Position of connection for main current circuit

Front side

Number of auxiliary contacts as change-over contact

0

Degree of protection (IP)

IP40

Number of poles

4

Motor drive optional

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.