Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting- - -A
Adjustment range undelayed short-circuit release- - -A
Adjustment range short-term delayed short-circuit release- - -A
Rated permanent current Iu800A
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Type of electrical connection of main circuitBolt connection
DIN rail (top hat rail) mounting optionalNo
Integrated earth fault protectionNo
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Position of connection for main current circuitFront side
Complete device with protection unitNo
Number of poles4
With integrated under voltage releaseNo
Motor drive integratedYes
Type of control elementPush button
Motor drive optionalNo
Number of auxiliary contacts as change-over contact0
With switched-off indicatorYes
Device constructionBuilt-in device slide-in technique (withdrawable)
Degree of protection (IP)IP40
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

33386

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting

- .. -A

Adjustment range undelayed short-circuit release

- .. -A

Adjustment range short-term delayed short-circuit release

- .. -A

Rated permanent current Iu

800A

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Type of electrical connection of main circuit

Bolt connection

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Position of connection for main current circuit

Front side

Complete device with protection unit

Number of poles

4

With integrated under voltage release

Motor drive integrated

Type of control element

Push button

Motor drive optional

Number of auxiliary contacts as change-over contact

0

With switched-off indicator

Device construction

Built-in device slide-in technique (withdrawable)

Degree of protection (IP)

IP40

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.