Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting- - -A
Adjustment range undelayed short-circuit release- - -A
Adjustment range short-term delayed short-circuit release- - -A
Integrated earth fault protectionNo
Number of poles3
Suitable for DIN rail (top hat rail) mountingNo
Device constructionBuilt-in device slide-in technique (withdrawable)
Rated voltage690 - 690V
Rated permanent current Iu1000A
Complete device with protection unitNo
With switched-off indicatorYes
Type of electrical connection of main circuitBolt connection
Motor drive integratedYes
Number of auxiliary contacts as normally open contact0
Position of connection for main current circuitFront side
Number of auxiliary contacts as normally closed contact0
Degree of protection (IP)IP40
Motor drive optionalNo
Type of control elementPush button
Number of auxiliary contacts as change-over contact0
With integrated under voltage releaseNo
DIN rail (top hat rail) mounting optionalNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

33392

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting

- .. -A

Adjustment range undelayed short-circuit release

- .. -A

Adjustment range short-term delayed short-circuit release

- .. -A

Integrated earth fault protection

Number of poles

3

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device slide-in technique (withdrawable)

Rated voltage

690 .. 690V

Rated permanent current Iu

1000A

Complete device with protection unit

With switched-off indicator

Type of electrical connection of main circuit

Bolt connection

Motor drive integrated

Number of auxiliary contacts as normally open contact

0

Position of connection for main current circuit

Front side

Number of auxiliary contacts as normally closed contact

0

Degree of protection (IP)

IP40

Motor drive optional

Type of control element

Push button

Number of auxiliary contacts as change-over contact

0

With integrated under voltage release

DIN rail (top hat rail) mounting optional

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA