Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting- - -A
Adjustment range undelayed short-circuit release- - -A
Adjustment range short-term delayed short-circuit release- - -A
Rated permanent current Iu1250A
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Type of electrical connection of main circuitBolt connection
Integrated earth fault protectionNo
Device constructionBuilt-in device slide-in technique (withdrawable)
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as change-over contact0
Position of connection for main current circuitFront side
With integrated under voltage releaseNo
With switched-off indicatorYes
Number of auxiliary contacts as normally open contact0
Suitable for DIN rail (top hat rail) mountingNo
Complete device with protection unitNo
Number of auxiliary contacts as normally closed contact0
Number of poles4
Motor drive integratedYes
Type of control elementPush button
Motor drive optionalNo
Degree of protection (IP)IP40
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

33405

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting

- .. -A

Adjustment range undelayed short-circuit release

- .. -A

Adjustment range short-term delayed short-circuit release

- .. -A

Rated permanent current Iu

1250A

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Type of electrical connection of main circuit

Bolt connection

Integrated earth fault protection

Device construction

Built-in device slide-in technique (withdrawable)

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as change-over contact

0

Position of connection for main current circuit

Front side

With integrated under voltage release

With switched-off indicator

Number of auxiliary contacts as normally open contact

0

Suitable for DIN rail (top hat rail) mounting

Complete device with protection unit

Number of auxiliary contacts as normally closed contact

0

Number of poles

4

Motor drive integrated

Type of control element

Push button

Motor drive optional

Degree of protection (IP)

IP40

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.