Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- SCHNEIDER
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Conditioned rated short-circuit current Iq
47kA
Rated permanent current at AC-21, 400 V
-A
Rated operation power at AC-23, 400 V
-kW
Switching power at 400 V
-kW
Version as maintenance-/service switch
Yes
Version as main switch
Yes
Max. rated operation voltage Ue AC
690V
Version as safety switch
No
Version as emergency stop installation
No
Version as reversing switch
No
Number of switches
1
Rated short-time withstand current lcw
25kA
Rated operating voltage
220 - 690V
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally closed contact
0
Number of poles
4
Voltage release optional
Yes
Rated permanent current at AC-23, 400 V
1600A
Motor drive optional
No
Suitable for front mounting 4-hole
Yes
Rated permanent current Iu
1600A
Suitable for front mounting centre
No
Suitable for floor mounting
Yes
Motor drive integrated
No
Suitable for distribution board installation
Yes
Device construction
Built-in device fixed built-in technique
Colour control element
Black
Suitable for intermediate mounting
No
Type of electrical connection of main circuit
Screw connection
Type of control element
Toggle
Degree of protection (IP), front side
IP40
Interlockable
Yes
From same serie
33429

Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- SCHNEIDER
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Conditioned rated short-circuit current Iq
47kA
Rated permanent current at AC-21, 400 V
-A
Rated operation power at AC-23, 400 V
-kW
Switching power at 400 V
-kW
Version as maintenance-/service switch
Version as main switch
Max. rated operation voltage Ue AC
690V
Version as safety switch
Version as emergency stop installation
Version as reversing switch
Number of switches
1
Rated short-time withstand current lcw
25kA
Rated operating voltage
220 .. 690V
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally closed contact
0
Number of poles
4
Voltage release optional
Rated permanent current at AC-23, 400 V
1600A
Motor drive optional
Suitable for front mounting 4-hole
Rated permanent current Iu
1600A
Suitable for front mounting centre
Suitable for floor mounting
Motor drive integrated
Suitable for distribution board installation
Device construction
Built-in device fixed built-in technique
Colour control element
Black
Suitable for intermediate mounting
Type of electrical connection of main circuit
Screw connection
Type of control element
Toggle
Degree of protection (IP), front side
IP40
Interlockable