  • Low-voltage industrial components
  • Switch disconnector
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated operation power at AC-3, 400 V-kW
Conditioned rated short-circuit current Iq47kA
Rated permanent current at AC-21, 400 V-A
Rated operation power at AC-23, 400 V-kW
Switching power at 400 V-kW
Version as main switchYes
Version as safety switchNo
Version as maintenance-/service switchYes
Number of poles3
Max. rated operation voltage Ue AC690V
Version as reversing switchNo
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Rated permanent current at AC-23, 400 V800A
Rated operating voltage220 - 690V
Number of auxiliary contacts as change-over contact5
Rated short-time withstand current lcw25kA
Rated permanent current Iu800A
Suitable for floor mountingYes
Motor drive optionalNo
Suitable for front mounting 4-holeYes
Motor drive integratedYes
Voltage release optionalYes
InterlockableYes
Number of switches1
Device constructionBuilt-in device fixed built-in technique
Type of electrical connection of main circuitScrew connection
Type of control elementToggle
Suitable for distribution board installationYes
Colour control elementBlack
Version as emergency stop installationNo
Degree of protection (IP), front sideIP40
Suitable for front mounting centreNo
Suitable for intermediate mountingNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

33442

Main Product Image

Details

  • Low-voltage industrial components
  • Switch disconnector
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated operation power at AC-3, 400 V

-kW

Conditioned rated short-circuit current Iq

47kA

Rated permanent current at AC-21, 400 V

-A

Rated operation power at AC-23, 400 V

-kW

Switching power at 400 V

-kW

Version as main switch

Version as safety switch

Version as maintenance-/service switch

Number of poles

3

Max. rated operation voltage Ue AC

690V

Version as reversing switch

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Rated permanent current at AC-23, 400 V

800A

Rated operating voltage

220 .. 690V

Number of auxiliary contacts as change-over contact

5

Rated short-time withstand current lcw

25kA

Rated permanent current Iu

800A

Suitable for floor mounting

Motor drive optional

Suitable for front mounting 4-hole

Motor drive integrated

Voltage release optional

Interlockable

Number of switches

1

Device construction

Built-in device fixed built-in technique

Type of electrical connection of main circuit

Screw connection

Type of control element

Toggle

Suitable for distribution board installation

Colour control element

Black

Version as emergency stop installation

Degree of protection (IP), front side

IP40

Suitable for front mounting centre

Suitable for intermediate mounting