Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Adjustment range short-term delayed short-circuit release- - -A
Adjustment range undelayed short-circuit release945 - 6300A
Integrated earth fault protectionNo
Overload release current setting252 - 630A
Rated voltage690 - 690V
Rated permanent current Iu630A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Type of electrical connection of main circuitScrew connection
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Position of connection for main current circuitFront side
With switched-off indicatorYes
Number of poles3
With integrated under voltage releaseNo
Complete device with protection unitYes
Type of control elementToggle
Motor drive optionalYes
Motor drive integratedNo
Degree of protection (IP)IP40
Number of auxiliary contacts as normally closed contact0
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

33461

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Adjustment range short-term delayed short-circuit release

- .. -A

Adjustment range undelayed short-circuit release

945 .. 6300A

Integrated earth fault protection

Overload release current setting

252 .. 630A

Rated voltage

690 .. 690V

Rated permanent current Iu

630A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Type of electrical connection of main circuit

Screw connection

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Position of connection for main current circuit

Front side

With switched-off indicator

Number of poles

3

With integrated under voltage release

Complete device with protection unit

Type of control element

Toggle

Motor drive optional

Motor drive integrated

Degree of protection (IP)

IP40

Number of auxiliary contacts as normally closed contact

0

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.