Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Adjustment range short-term delayed short-circuit release- - -A
Rated voltage690 - 690V
Rated permanent current Iu630A
Power loss40W
Overload release current setting252 - 630A
Device constructionBuilt-in device fixed built-in technique
Adjustment range undelayed short-circuit release945 - 6300A
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally closed contact0
Integrated earth fault protectionNo
With switched-off indicatorYes
Number of poles4
Number of auxiliary contacts as change-over contact0
Type of control elementToggle
Complete device with protection unitYes
Position of connection for main current circuitFront side
With integrated under voltage releaseNo
Number of auxiliary contacts as normally open contact0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Degree of protection (IP)IP40
Motor drive integratedNo
Motor drive optionalYes
DIN rail (top hat rail) mounting optionalNo
Type of electrical connection of main circuitScrew connection
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

33463

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Adjustment range short-term delayed short-circuit release

- .. -A

Rated voltage

690 .. 690V

Rated permanent current Iu

630A

Power loss

40W

Overload release current setting

252 .. 630A

Device construction

Built-in device fixed built-in technique

Adjustment range undelayed short-circuit release

945 .. 6300A

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally closed contact

0

Integrated earth fault protection

With switched-off indicator

Number of poles

4

Number of auxiliary contacts as change-over contact

0

Type of control element

Toggle

Complete device with protection unit

Position of connection for main current circuit

Front side

With integrated under voltage release

Number of auxiliary contacts as normally open contact

0

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Degree of protection (IP)

IP40

Motor drive integrated

Motor drive optional

DIN rail (top hat rail) mounting optional

Type of electrical connection of main circuit

Screw connection

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.