  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Adjustment range short-term delayed short-circuit release- - -A
Rated permanent current Iu800A
Number of auxiliary contacts as change-over contact0
DIN rail (top hat rail) mounting optionalNo
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Number of poles3
Number of auxiliary contacts as normally open contact0
Type of control elementToggle
Type of electrical connection of main circuitScrew connection
Adjustment range undelayed short-circuit release1200 - 8000A
Overload release current setting320 - 800A
Integrated earth fault protectionNo
With switched-off indicatorYes
Motor drive integratedNo
With integrated under voltage releaseNo
Motor drive optionalYes
Complete device with protection unitYes
Position of connection for main current circuitFront side
Number of auxiliary contacts as normally closed contact0
Degree of protection (IP)IP40
Rated voltage690 - 690V
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

33468

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Adjustment range short-term delayed short-circuit release

- .. -A

Rated permanent current Iu

800A

Number of auxiliary contacts as change-over contact

0

DIN rail (top hat rail) mounting optional

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Number of poles

3

Number of auxiliary contacts as normally open contact

0

Type of control element

Toggle

Type of electrical connection of main circuit

Screw connection

Adjustment range undelayed short-circuit release

1200 .. 8000A

Overload release current setting

320 .. 800A

Integrated earth fault protection

With switched-off indicator

Motor drive integrated

With integrated under voltage release

Motor drive optional

Complete device with protection unit

Position of connection for main current circuit

Front side

Number of auxiliary contacts as normally closed contact

0

Degree of protection (IP)

IP40

Rated voltage

690 .. 690V