Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Adjustment range short-term delayed short-circuit release- - -A
Rated permanent current Iu1250A
Rated voltage690 - 690V
Integrated earth fault protectionNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Type of electrical connection of main circuitScrew connection
Overload release current setting500 - 1250A
Number of auxiliary contacts as change-over contact0
With integrated under voltage releaseNo
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as normally closed contact0
Suitable for DIN rail (top hat rail) mountingNo
Position of connection for main current circuitFront side
Number of auxiliary contacts as normally open contact0
Adjustment range undelayed short-circuit release1875 - 12500A
Number of poles3
Type of control elementToggle
Motor drive optionalYes
Device constructionBuilt-in device fixed built-in technique
Motor drive integratedNo
Complete device with protection unitYes
With switched-off indicatorYes
Degree of protection (IP)IP40
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

33478

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Adjustment range short-term delayed short-circuit release

- .. -A

Rated permanent current Iu

1250A

Rated voltage

690 .. 690V

Integrated earth fault protection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Type of electrical connection of main circuit

Screw connection

Overload release current setting

500 .. 1250A

Number of auxiliary contacts as change-over contact

0

With integrated under voltage release

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally closed contact

0

Suitable for DIN rail (top hat rail) mounting

Position of connection for main current circuit

Front side

Number of auxiliary contacts as normally open contact

0

Adjustment range undelayed short-circuit release

1875 .. 12500A

Number of poles

3

Type of control element

Toggle

Motor drive optional

Device construction

Built-in device fixed built-in technique

Motor drive integrated

Complete device with protection unit

With switched-off indicator

Degree of protection (IP)

IP40