Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Adjustment range short-term delayed short-circuit release- - -A
Overload release current setting500 - 1250A
Rated voltage690 - 690V
Rated permanent current Iu1250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Adjustment range undelayed short-circuit release1875 - 12500A
Number of auxiliary contacts as normally open contact0
Number of poles4
Power loss176W
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as normally closed contact0
With switched-off indicatorYes
Suitable for DIN rail (top hat rail) mountingNo
Motor drive integratedNo
Complete device with protection unitYes
Integrated earth fault protectionNo
With integrated under voltage releaseNo
Motor drive optionalYes
Type of control elementToggle
DIN rail (top hat rail) mounting optionalNo
Position of connection for main current circuitFront side
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as change-over contact0
Degree of protection (IP)IP40
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

33480

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Adjustment range short-term delayed short-circuit release

- .. -A

Overload release current setting

500 .. 1250A

Rated voltage

690 .. 690V

Rated permanent current Iu

1250A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Adjustment range undelayed short-circuit release

1875 .. 12500A

Number of auxiliary contacts as normally open contact

0

Number of poles

4

Power loss

176W

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as normally closed contact

0

With switched-off indicator

Suitable for DIN rail (top hat rail) mounting

Motor drive integrated

Complete device with protection unit

Integrated earth fault protection

With integrated under voltage release

Motor drive optional

Type of control element

Toggle

DIN rail (top hat rail) mounting optional

Position of connection for main current circuit

Front side

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as change-over contact

0

Degree of protection (IP)

IP40

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.