Aleta.hr

Details

  • Low-voltage industrial components
  • Switch disconnector
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated operation power at AC-3, 400 V-kW
Conditioned rated short-circuit current Iq75kA
Rated permanent current at AC-21, 400 V-A
Rated operation power at AC-23, 400 V-kW
Switching power at 400 V-kW
Version as safety switchNo
Version as emergency stop installationNo
Number of switches1
Version as reversing switchNo
Max. rated operation voltage Ue AC690V
Rated permanent current Iu800A
Rated operating voltage220 - 690V
Rated short-time withstand current lcw25kA
Number of poles3
Rated permanent current at AC-23, 400 V800A
Motor drive optionalNo
Number of auxiliary contacts as normally closed contact0
Motor drive integratedNo
Voltage release optionalYes
Number of auxiliary contacts as normally open contact0
Version as maintenance-/service switchYes
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as change-over contact0
Suitable for front mounting centreNo
Suitable for floor mountingYes
Suitable for front mounting 4-holeYes
Suitable for distribution board installationYes
Suitable for intermediate mountingNo
Type of control elementToggle
InterlockableYes
Colour control elementBlack
Type of electrical connection of main circuitScrew connection
Version as main switchYes
Degree of protection (IP), front sideIP40
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

33487

Main Product Image

Details

  • Low-voltage industrial components
  • Switch disconnector
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated operation power at AC-3, 400 V

-kW

Conditioned rated short-circuit current Iq

75kA

Rated permanent current at AC-21, 400 V

-A

Rated operation power at AC-23, 400 V

-kW

Switching power at 400 V

-kW

Version as safety switch

Version as emergency stop installation

Number of switches

1

Version as reversing switch

Max. rated operation voltage Ue AC

690V

Rated permanent current Iu

800A

Rated operating voltage

220 .. 690V

Rated short-time withstand current lcw

25kA

Number of poles

3

Rated permanent current at AC-23, 400 V

800A

Motor drive optional

Number of auxiliary contacts as normally closed contact

0

Motor drive integrated

Voltage release optional

Number of auxiliary contacts as normally open contact

0

Version as maintenance-/service switch

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as change-over contact

0

Suitable for front mounting centre

Suitable for floor mounting

Suitable for front mounting 4-hole

Suitable for distribution board installation

Suitable for intermediate mounting

Type of control element

Toggle

Interlockable

Colour control element

Black

Type of electrical connection of main circuit

Screw connection

Version as main switch

Degree of protection (IP), front side

IP40

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.