Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Adjustment range undelayed short-circuit release1260 - 9450A
Rated permanent current Iu630A
Rated voltage690 - 690V
DIN rail (top hat rail) mounting optionalNo
With switched-off indicatorYes
Degree of protection (IP)IP40
Overload release current setting252 - 630A
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
With integrated under voltage releaseNo
Number of auxiliary contacts as normally closed contact0
Integrated earth fault protectionNo
Adjustment range short-term delayed short-circuit release378 - 6300A
Number of poles3
Number of auxiliary contacts as change-over contact0
Position of connection for main current circuitFront side
Motor drive integratedNo
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as normally open contact0
Type of control elementToggle
Motor drive optionalYes
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

33546

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Adjustment range undelayed short-circuit release

1260 .. 9450A

Rated permanent current Iu

630A

Rated voltage

690 .. 690V

DIN rail (top hat rail) mounting optional

With switched-off indicator

Degree of protection (IP)

IP40

Overload release current setting

252 .. 630A

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

With integrated under voltage release

Number of auxiliary contacts as normally closed contact

0

Integrated earth fault protection

Adjustment range short-term delayed short-circuit release

378 .. 6300A

Number of poles

3

Number of auxiliary contacts as change-over contact

0

Position of connection for main current circuit

Front side

Motor drive integrated

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as normally open contact

0

Type of control element

Toggle

Motor drive optional

Complete device with protection unit