Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Rated voltage690 - 690V
Overload release current setting400 - 1000A
Rated permanent current Iu1000A
Adjustment range short-term delayed short-circuit release600 - 10000A
Type of electrical connection of main circuitScrew connection
Adjustment range undelayed short-circuit release2000 - 15000A
Integrated earth fault protectionNo
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingNo
Type of control elementToggle
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of poles3
With switched-off indicatorYes
With integrated under voltage releaseNo
Number of auxiliary contacts as change-over contact0
Motor drive integratedNo
Degree of protection (IP)IP40
Position of connection for main current circuitFront side
Motor drive optionalYes
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

33558

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Rated voltage

690 .. 690V

Overload release current setting

400 .. 1000A

Rated permanent current Iu

1000A

Adjustment range short-term delayed short-circuit release

600 .. 10000A

Type of electrical connection of main circuit

Screw connection

Adjustment range undelayed short-circuit release

2000 .. 15000A

Integrated earth fault protection

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

Type of control element

Toggle

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of poles

3

With switched-off indicator

With integrated under voltage release

Number of auxiliary contacts as change-over contact

0

Motor drive integrated

Degree of protection (IP)

IP40

Position of connection for main current circuit

Front side

Motor drive optional

Complete device with protection unit

DIN rail (top hat rail) mounting optional

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.