Technical specifications

Rated permanent current Iu1000A
Rated voltage690 - 690V
Adjustment range short-term delayed short-circuit release600 - 10000A
Overload release current setting400 - 1000A
Adjustment range undelayed short-circuit release2000 - 15000A
Device constructionBuilt-in device fixed built-in technique
Power loss136W
Integrated earth fault protectionNo
Type of electrical connection of main circuitScrew connection
DIN rail (top hat rail) mounting optionalNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Suitable for DIN rail (top hat rail) mountingNo
With switched-off indicatorYes
With integrated under voltage releaseNo
Number of poles4
Type of control elementToggle
Complete device with protection unitYes
Motor drive integratedNo
Motor drive optionalYes
Degree of protection (IP)IP40
Position of connection for main current circuitFront side
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

33563

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated permanent current Iu

1000A

Rated voltage

690 .. 690V

Adjustment range short-term delayed short-circuit release

600 .. 10000A

Overload release current setting

400 .. 1000A

Adjustment range undelayed short-circuit release

2000 .. 15000A

Device construction

Built-in device fixed built-in technique

Power loss

136W

Integrated earth fault protection

Type of electrical connection of main circuit

Screw connection

DIN rail (top hat rail) mounting optional

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Suitable for DIN rail (top hat rail) mounting

With switched-off indicator

With integrated under voltage release

Number of poles

4

Type of control element

Toggle

Complete device with protection unit

Motor drive integrated

Motor drive optional

Degree of protection (IP)

IP40

Position of connection for main current circuit

Front side